433MHz 2km Remote I O Module Control RS485 Connect PLC 2AI Collect 4-20mA Analog Signal 2DO

Basic Information
Place of Origin: China
Brand Name: Lensen
Model Number: LS-RAI02+LS-R324
Minimum Order Quantity: 2pcs
Price: Negotiation
Packaging Details: standard carton
Delivery Time: 2-7 days
Payment Terms: T/T, Western Union
Supply Ability: 6000pcs/month
Frequency: 433MHz Power Output: 1W
Input: Analog 4-20mA Distance: 2km
Protocol: RS485 Modbus RTU Program: Needed
High Light:

remote i o module

,

remote io system

33MHz 2km Remote I O Module Control RS485 Connect PLC 2AI Collect 4-20mA Analog Signal 2DO

 

 

Advantage of wireless solution

No wires to bury or maintain, no need to drill holes on wall

Reliable communication in all direction,any terrain, regardless of hills, walls, trees

Cost saving in installation and maintenance

Radio based, no need internet and monthly fee, full ownership of the system

 

 

Wireless RTU features

- Portable device, DIN-rail mounting for easy installation

- Isolated inputs

- LEDs for power supply, communication, input, output status

- Flexible networking, point to point or point to multipoints

- DIP to change different modes

- Different types of I/O, DI, DO, AI, AO are available

- I/O expandable

- Short delay time

- Support I/O reduction, field input, remote output

- Easy handing on RS485 network, support Modbus RTU protocol

- Support on-line upgrade. Can configure by customer in setting mode

 

 

Projects Description:
1. Customer needs to minitor 10 tanks.
2. Intake or glow-off water by start/off the pumps or the valves.
3. Distance is within 1km.
4. Need wireless solution
 
 
LS-RAI02
Frequency 433MHz or 450MHz or 470MHz
Power output 100mW(600m),1000mW(3000m)
Products 2AI,4AI,2AO,4AO
Input type 4-20mA or 0-5V or 0-10V
Output type 4-20mA or 0-5V or 0-10V
Resolution ratio 24 bit
Accuracy ±0.02%
Power supply 9-36V DC usually use 24V DC
Interface RS-485
Channel No. 16ch default, can program via DIP switch
Antenna Sucker antenna with 1.5m cable
Working temperature -35℃~+75℃ industrial
Working humidity 10%~90% relative humidity, no condensation
Dimension 2AI,4AI 115×90×40(mm)
2AO,4AO
Fix way Standard 3.5 inch industrial DIN guild rail
 
LS-RDIO0202
Parameter
Power output: 1W (or 100mW version)
Power supply: 9V-30V (usually choose 24V DC or 12V DC)
Control distance: 3km (or 1km version)
Baud rate: 1200bps
Receiving sensibility: -123dBm@1200bps, -118dbm(9600bps)
Networking
Networking: Point to point and point to multipoint
Protocol: Modbus RTU protocol
Port Description
Input: 2 active inputs (passive customize), isolated
Output:

2 passive relay outputs, isolated

contact max load AC250V/5A,DC30V/5A

(active outputs 0-5V customize)

Communication port RS485 (wireless RS485 customize)
Current
Transmit current: <600mA (or 100mA version)
Receiving current: <50mA (or 20mA version)
General
Frequency: 433MHz, 400, 450, 470 or other band
Channel No: 16 channels, can change via DIP switch
Physical Properties
Dimension: 115×90×40(mm)
Antenna Connector: SMA,vehicle antenna with 1.5m cable
Temperature: -35℃~+75℃( industrial)
Mounting method: Standard 3.5 inch industrial guild rail
 
It is 1 master to many slaves application. Support Modbus RTU protocol.
 
Master is the PLC at RO plant. This side we recommend a LS-R324 to connect with PLC and RO Plant. LS-R324 is to collect all slave's data, forward to PLC for analysis. PLC process data, give command to RO Plant.
 
Slaves are the sensors on tank, the valves and the pumps.
 
a. About level sensors, there are 2 types, because there is salt water, to avoid Corrosion, we don't suggest thrown-in type sensor. Ultrasonic level sensor is more recommended.
Each sensor, you need an analog I/O module to collect and transmit the level sensor's 4-20mA signal to PLC. Use our LS-RAI02 module, it has 2 analog inputs.
 
b. About the pump, each one, you need a digital I/O module to start or close the pump. It is to control when we should intake water according tank level. Here we recommend LS-RDIO0202, it has 2 digital inputs and 2 relay outputs.
 
c. About the valves, each one, you need a digital I/O to start or close the valve. It is to control when we should blow off water according the tank level. Here we recommend LS-RDIO0202, it has 2 digital inputs and 2 relay outputs.
 
433MHz 2km Remote I O Module Control RS485 Connect PLC 2AI Collect 4-20mA Analog Signal 2DO 0